Solax Data HUB 1000 (FW2024)
B-210-1u15Monitoring for commercial inverters with actual firmware + priority support service GBC Hotline
Price:
- In stock
INTEGRATION OF UP TO 60 INVERTERS
SMART SCENE - AI ENERGY MANAGEMENT
INTELLIGENT REGULATION AND OVERFLOW CONTROL
SMART SCHEDULE
REMOTE MONITORING AND MANAGEMENT
HIGH-CAPACITY DATA STORAGE
Configurator
GBC TECH TIP
The SolaX DataHub1000 supports MODBUS TCP communication, which reflects the transmitted information required by the grid distributor. This allows you to read data from a connected meter or inverter, or control your PV plant with power control commands.SolaX DataHub1000 and using spot prices.
Description
Parameters
General parameters
Weight [kg]
0
Šířka [cm]
27
Výška [cm]
25
Hloubka [cm]
6.5
Download
FAQ
By default, the DataHUB 1000 does not treat the state when communication breaks down and export control is set.
If I want the inverters to stop working when either the communication with DataHUB 1000 fails or the meter communication fails I have to make the following settings:

- Modbus opcode: Write single register
- Register start adress: 6152
- Number of registres: 1
- Value of write operation: 1

- Modbus opcode: Write single register
- Register start adress: 6153
- Number of registres: 1
- Value of write operation: 1
PV panels
DC switching
Sure protectorsg
DC/AC boxes
Cables
Connectors
Optimizers
Overflow controllers
Monitoring