Solax Mega X3-MGA-50K-G2 AFCI
B-210-3M51a3-phase, 5x MPP, AFCI
Price:
- In stock
150% PV OVERSIZING
UP TO 6 MPPT DEPENDING ON INVERTER (2 STRINGS PER 1 MPPT)
110% OVERLOADING OUTPUT
32A PER MPPT (16A PER STRING)
180~1000Vdc MPPT VOLTAGE RANGE
MAX. EFFICIENCY 98.4%
GBC TECH TIP
For remote management, overflow control and monitoring of multiple devices, use the SolaX DataHub 1000, which allows connection of up to 60 inverters of the same series.Description
Parameters
General parameters
Weight [kg]
0
Šířka [cm]
73.1
Výška [cm]
61.2
Hloubka [cm]
41.3
Download
FAQ
Need to connect 2x SolaX gen.2 chargers to your SolaX inverter?
The new SolaX gen.2 chargers support data interconnection between each other to share information about the transfer point.
A prerequisite for this parallel mode is to have the same power variants as well as FW version 1.12 and above.
Wiring diagram:
1. Connection variant directly to the inverter
The data chargers are connected via the green terminal strip located on the bottom of the charger near the power contacts as follows: from the primary charger (which is connected to the inverter) port RS 485-2 A + RS485-2 B to the secondary charger port RS 485-1 A + RS485-1 B. The primary charger is connected to the inverter either via RJ45 port or via RS 485-1 A + RS 485-1 B. The wiring diagram looks like this:


2. Connection variant with CT
Také lze připojit k nabíječce její vlastní měření a řídit dle primární nabíječky i tu sekundární. Na primární nabíječku se připojí vlastní měření buď do RJ 45 (pro CT nebo elektroměr) případně na RS485-1 elektroměr. Nabíječky mezi sebou se propojí následovně: z primární RS 485-2 A + RS485-2 B na sekundární nabíječku na port RS 485-1 A + RS485-1 B. The wiring diagram looks like this:

Setup:
The setup is done only on the primary charger as follows:
Parallel function – ENABLE
Power ratio: 1:1 (Note: This is used to divide the power if both chargers are running at the same time and the mains capacity is exhausted.)

"The functionality of the two chargers in parallel mode is as follows: The secondary charger copies the set mode of the primary charger."
A new feature has been added to the SolaX Hybrid G4 inverter: the function for adjusting the emergency disconnection logic of the inverter from the grid, known as the SHUT DOWN function or 0/100% regulation. You can now choose from 3 modes:
1. Function for power disconnection of the battery and inverter
When a potential-free connection is made between pins 1+2 on port COM, the master battery/BMS contactor is disconnected, thus disconnecting the battery system from the inverter, and simultaneously power-disconnecting the inverter from the grid.
Settings: advanced menu – shut down – function control – use COM

Wiring:

2. Function for power disconnection of the inverter from the grid while maintaining battery charging
This function is located on the SHUT port of the inverter and pins 4+6. When a potential-free connection is made between these pins, the inverter is power-disconnected from the grid, but the battery charging function is retained.
Settings: advanced menu – shut down – wait charge mode – Enable

Wiring:

3. Function for power disconnection of the inverter from the grid without using the battery
This function does not require any configuration in the inverter and is active by default on the SHUT port and pins 4+6 with a potential-free connection. When activated, the inverter is power-disconnected from the grid and does not charge the battery.
Wiring:

Download >> NAV_CHINT_SOLAX_G4![]()
External ATS function
If you want to have the EPS output of the inverter always under voltage, please set the External ATS function to Disable in the Advanced menu.

Do you own a SolaX inverter and wonder which communication dongle is compatible with it? We have a solution for you!
Remove the protective cover from the dongle connector and check its shape.
1) If you see a recess with a USB port, then the suitable type for you is the WHITE dongle Pocket WiFi 2.0 – item code (B-210-1000)

2) If you see a black plastic extension with a USB port, then the suitable type for you is the BLACK dongle Pocket WiFi 3.0 – item code (B-210-1014)