Solax Mega X3-MGA-50K-G2 AFCI

B-210-3M51a

3-phase, 5x MPP, AFCI

Price:

  • In stock

Solax Mega X3-MGA-50K-G2 AFCI

 

150% PV OVERSIZING

 

UP TO 6 MPPT DEPENDING ON INVERTER (2 STRINGS PER 1 MPPT)

 

110% OVERLOADING OUTPUT

 

32A PER MPPT (16A PER STRING)

 

180~1000Vdc MPPT VOLTAGE RANGE

 

MAX. EFFICIENCY 98.4%

Configurator

GBC TECH TIP

For remote management, overflow control and monitoring of multiple devices, use the SolaX DataHub 1000, which allows connection of up to 60 inverters of the same series.

Description

SolaX X3-50K MEGA is a network inverter for small and medium commercial applications.

  • Up to 5 MPPT
  • High efficiency - max. 98.4 %
  • High reliability (Integrated Type II DC and AC surge protector)
  • Large voltage range (180-1000V)
  • Intelligent monitoring via app and web
  • Intelligent maintenance
  • Highest quality components
  • 2 strings per MPPT (max 32A)
  • Standard warranty 6 years (additional +5 / +10 years can be added)
  • AFCI (Arc Fault Circuit Interrupter)

 

STRING_MEGA_1800x500.png

Parameters

General parameters

Weight [kg]

0

Šířka [cm]

73.1

Výška [cm]

61.2

Hloubka [cm]

41.3

Videos

SolaX X3 MEGA G2 (Installation Guide) – Powerful On-Grid Inverter for Large PV Systems!

youtube NgJ5p2P25HM

FAQ

Need to connect 2x SolaX gen.2 chargers to your SolaX inverter?

 

The new SolaX gen.2 chargers support data interconnection between each other to share information about the transfer point.

 

A prerequisite for this parallel mode is to have the same power variants as well as FW version 1.12 and above.

 

Wiring diagram:

 

1. Connection variant directly to the inverter

The data chargers are connected via the green terminal strip located on the bottom of the charger near the power contacts as follows: from the primary charger (which is connected to the inverter) port RS 485-2 A + RS485-2 B to the secondary charger port RS 485-1 A + RS485-1 B. The primary charger is connected to the inverter either via RJ45 port or via RS 485-1 A + RS 485-1 B. The wiring diagram looks like this:

dve_nabijecky 1.png

dve_nabijecky 2.png

2. Connection variant with CT

Také lze připojit k nabíječce její vlastní měření a řídit dle primární nabíječky i tu sekundární. Na primární nabíječku se připojí vlastní měření buď do RJ 45 (pro CT nebo elektroměr) případně na RS485-1 elektroměr.  Nabíječky mezi sebou se propojí následovně: z primární RS 485-2 A + RS485-2 B na sekundární nabíječku na port RS 485-1 A + RS485-1 B. The wiring diagram looks like this:

dve_nabijecky 3.png

 

Setup:

 

The setup is done only on the primary charger as follows:

Parallel function – ENABLE

Power ratio: 1:1 (Note: This is used to divide the power if both chargers are running at the same time and the mains capacity is exhausted.)

dve_nabijecky 4.png

 

"The functionality of the two chargers in parallel mode is as follows: The secondary charger copies the set mode of the primary charger."

A new feature has been added to the SolaX Hybrid G4 inverter: the function for adjusting the emergency disconnection logic of the inverter from the grid, known as the SHUT DOWN function or 0/100% regulation. You can now choose from 3 modes:

 

1. Function for power disconnection of the battery and inverter

 

 

 

When a potential-free connection is made between pins 1+2 on port COM, the master battery/BMS contactor is disconnected, thus disconnecting the battery system from the inverter, and simultaneously power-disconnecting the inverter from the grid.

 

Settings: advanced menu – shut down – function control – use COM

shot down 1.png

 

 

 

 

 

 

Wiring:

shot down 2.png

 

 

 

2. Function for power disconnection of the inverter from the grid while maintaining battery charging

 

 

 

 

This function is located on the SHUT port of the inverter and pins 4+6. When a potential-free connection is made between these pins, the inverter is power-disconnected from the grid, but the battery charging function is retained.

 

Settings: advanced menu – shut down – wait charge mode – Enable

 

shot down 3.png

 

 

 

 

 

Wiring:

shot down 4.png

 

 

3. Function for power disconnection of the inverter from the grid without using the battery

This function does not require any configuration in the inverter and is active by default on the SHUT port and pins 4+6 with a potential-free connection. When activated, the inverter is power-disconnected from the grid and does not charge the battery.

 

 

 

 

 

Wiring:

 

shot down 4.png

 

Download >>  NAV_CHINT_SOLAX_G4

External ATS function

If you want to have the EPS output of the inverter always under voltage, please set the External ATS function to Disable in the Advanced menu.

 

 

 

 

Do you own a SolaX inverter and wonder which communication dongle is compatible with it? We have a solution for you!

 

Remove the protective cover from the dongle connector and check its shape.

 

1) If you see a recess with a USB port, then the suitable type for you is the WHITE dongle Pocket WiFi 2.0 – item code (B-210-1000)

dongle 1.png

 

2) If you see a black plastic extension with a USB port, then the suitable type for you is the BLACK dongle Pocket WiFi 3.0 – item code (B-210-1014)

dongle 2.png

 

Identification by product code for X3-Hybrid G4

dongle 3.png